Loading...
sysdat.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
2-33
Nur für den internen Gebrauch System Data
HiPath 3000
Boards for Tie Trunk Traffic
Options
Table 2-16 Tie Trunk Traffic Boards for HiPath 3350
Board
Name
Capacity Coun-
try
Type/Description
Ports per board
B channels per board
Max. number of
boards per system
ROW
USA
HXGS3 2 8 1
(2
1
)
1 The system may be configured with two HG 1500 boards if PDM1 is not used.
x x HG 1500 board for connecting the HiPath 3350 system di-
rectly to a local data network (Ethernet).
STLS2 2 4 2 x - Board for ISDN basic rate access.
Configuration of ISDN trunks, tie trunks, and stations (no
feeding) on the same board is possible.
STLS4 4 8 1 x x
Table 2-17 Optional Boards for HiPath 3350
Board
Name
Capacity Coun-
try
Type/Description
ROW
USA
ALUM4 Trunk failure
transfers
4 x x Trunk failure transfer; this board transfers loop start
trunks directly to internal analog stations in the event
of a power failure (note the signaling method used).
ANI4 Analog trunks 4 - x This board allows calling line identification (caller ID)
in conjunction with TMGL4.
GEE12 Number of call
charge receiv-
ers
4 x - This optional board records the country-specific call
charge pulses (12 kHz) from the trunk.
GEE16 Number of call
charge receiv-
ers
4 x - This optional board records the country-specific call
charge pulses (16 kHz) from the trunk.