GetAccount
Data record structure
Table 6-7 GetAccount - Data Record Structure
No. Pos. Length Description
1 1-8 8 Date of call end
Format DD.MM.YY, for example “13.09.00”
2 9-16 8 Time of call end
Format hh:mm:ss, for example “14:14:00”
3 17-19 3 Trunk number
right-aligned with leading blanks, for example “ 1”
4 20-22 3 Node ID for HiPath 3000 (matches the configuration in HiPath 3000/
5000 Manager E)
right-aligned with leading blanks
5 23-28 6 Internal extension number
right-aligned with leading blanks
6 29-33 5 Call duration in seconds
7 34-41 8 Call duration
Format hh:mm:ss, for example “00:04:34
8 42-66 25 For incoming calls: external caller number
For outgoing calls: external call number dialed including the call-
by-call number
left-aligned with succeeding blanks
9 67-77 11 Number of tariff units
right-aligned with leading blanks
10 78 1 Call type
1: incoming
2: outgoing (default)
11 79-89 11 Account code ACCT
left-aligned with succeeding blanks
12 90-100 11 MSN used
13 101-105 5 Trunk
right-aligned with leading blanks
14 106-109 4 LCR Selected Route (corresponds to configuration in HiPath 3000/
5000 Manager E)
right-aligned with leading blanks
15 110 1 CR
16 111 1 LF