Starting HiPath 3000 as a Gateway Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
7-10 HiPath 3000/5000 V9, Service documentation
start_3g.fm
Starting HiPath 3300 as a Gateway
6. Performing a system check
The following tests must be performed if telephones are directly connected to
the gateway:
Checking the telephones
Check the time and date display on each telephone. If a display does not
appear, either the telephone or the link is defective. Replace the terminal
or fix the link.
Perform random terminal tests as described in Section 12.4.11 on all tele-
phones.
Checking for proper system booting
Set up internal and external calls at random to check if the system is func-
tioning properly.
Test IP configuration
Ping the HG 1500 IP address in the gateway
Make random external calls (from IP phones or clients to HiPath 5000)
Table 7-3 HiPath 3300 as a GW, Procedure for System Installation and Startup
Step Activity (Remarks)