wclient.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
10-45
Nur für den internen Gebrauch Workpoint Clients
OpenStage Product Family
SLBL: 1.1.0_0013_hs
BOOT:1.3.1_0013_hs_nand128
AUX power detected
USB mass storage device detected
Enter update code: _
7. Enter the update code “0167” via the programmable touch/sensor keys beside the display.
Once the update code has been entered:
If the data entered is incorrect: The telephone continues the boot procedure.
If the data entered is correct: The update procedure starts - the update progress can
be followed on the display.
The update procedure is successfully completed when the following text appears:
Update script succeeded.
Copy logs to USB stick … done.
Unmounting USB device and exit
Please remove USB device to reboot!
The update procedure places a number of log files in the log folder on the USB stick.
8. Remove the USB stick from the telephone. If the update is successful, the telephone re-
starts automatically to load the new software.
>
The programmable keys start from “0” and continues in descending order.