Workpoint Clients Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
10-128 HiPath 3000/5000 V9, Service documentation
wclient.fm
Attendant Console Versions
optiClient Attendant as central attendant console
optiClient Attendant can be used as a central attendant console in an IP network (max. 6 opti-
Client Attendant per network). To enable network-wide BLF functionality, all attendant consoles
must be connected to one of the network’s HiPath 3000 nodes and registered. This functionality
is independent of the optiClient Attendant connection type (USB or TCP/IP). For the network-
wide Busy Lamp Field function all decentralized systems send their station states (e.g. free or
busy) to the central system, to which the optiClient Attendants are connected. Signaling takes
place in the CorNet-IP protocol (CorNet-NQ protocol tunneled in H.323 via annex M1).
In an IP network, up to 100 stations per node can be defined that send their status information
to the central attendant console for display on the busy lamp field. The stations of the central
system in the network (to which the optiClient Attendants are connected) can all be displayed
on the busy lamp field of the central attendant console.