Technology subrack
7-10 Hardware - SIMADYN D
Edition 03.2001
BASE BOARD-T400, synchronized via X2/B25 --> X1/B25 TECH BOARD-
T400, and
TECH BOARD-T400 synchronized via X1/A26 --> X2/A26 BASE BOARD-
T400;
7.2.7 Parameters
The I/O of the function blocks as well as the parameters can be defined
(configured) on the T400. Thus, these I/O can be read and changed using
the "parameter mechanism" via
Dual port RAM
PROFIBUS (CB1)
USS protocol (for operator control device, SIMOVIS)
2000 parameters can be configured, whereby a differentiation can be made
between those at the operator control panel (and SIMOVIS), and the basic
drive converter parameters („r“ and „P“) using one of the two prefixes
„H“
„L“
7.2.8 Terminal assignment
All of the signals are connected at 55 terminals, which are accessible from
the front.
They are distributed over 5 11-pin MINI-COMBICON plug connectors in a
3.5 mm grid dimension (connectors X5 - X9):
Synchronizing
2 T400: