Basic information about the drive system
13.12 System rules, sampling times and DRIVE-CLiQ wiring
Drive functions
1026 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
The recommended settings are marked with
in the Table; all other possible settings are
marked with X.
Table 13- 14 Pulse frequencies and current controller sampling times for servo control
Current controller sampling time [µs]
12.0 X - - - - - - - - - -
10.0 - - - - X - - -
- -
1.777 - X - - - - - - - - -
Note
Clock cycle mix
Detailed information about the clock cycle mix for servo control is provided in Sectio
n Cycle
mix for servo control and vector control
(Page 1031).