Communication
11.1 Communication according to PROFIdrive
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
767
11.1.5.1
PROFINET-based diagnostics
For PROFINET, to transfer PROFIdrive message classes, channel diagnostics (Channel
Diagnosis) are used (see PROFINET IO specification (http://www.profibus.com)).
A message always comprises the following components in this specific sequence:
Block Header (6 Byte)
Blocktype
Blocklength
BlockversionHigh
BlockversionLow
API (4 Byte)
Slot Number (2 Byte)
Sub Slot Number (2 Byte)
Channel Number (2 Byte)
Channel Properties (0x8000) (2 Byte)
User Structure Identifier (2 Byte)
Channel Diagnosis Data (6 Byte)
Channel Number (2 Byte)
Channel Properties (2 Byte)
Channel Error Type (2 Byte)
Overview:
Figure 11-10 Components of a message