EasyManuals Logo

Siemens SIROTEC Function Manual

Siemens SIROTEC
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #804 background imageLoading...
Page #804 background image
Communication
11.3 Communication via PROFINET IO
Drive functions
804 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
11.3
Communication via PROFINET IO
11.3.1
General information about PROFINET IO
PROFINET IO is an open Industrial Ethernet standard for a wide range of production and
process automation applications. PROFINET IO is based on Industrial Ethernet and
observes TCP/IP and IT standards.
Deterministic signal processing in real time is important in industrial networks. PROFINET IO
satisfies these requirements.
The international standard IEC 61158 ensures open, multi-vendor systems:
PROFINET IO is tuned for high-speed, time-critical data transfers at field level.
PROFINET IO
Within the context of Totally Integrated Automation (TIA), PROFINET IO is the systematic
development of the following systems:
PROFIBUS DP, the established fieldbus,
Industrial Ethernet, the communications bus for the cell level.
Experience gained from both systems was integrated into PROFINET IO. An Ethernet-based
automation standard defined by PROFIBUS International (PROFIBUS user organization),
PROFINET IO is a manufacturer-independent communication and engineering model.
PROFINET IO defines every aspect of the data exchange between IO controllers (devices
with so-called "master functionality" and the IO devices (devices with so-called "slave
functionality") as well as carrying out parameterization and diagnostics. A PROFINET IO
system is configured in virtually the same way as a PROFIBUS system.
A PROFINET IO system is assembled from the following devices:
An IO controller controls automation tasks.
An IO device is controlled and monitored by an IO controller. An IO device can consist of
several modules and submodules.
An IO supervisor is an engineering tool, typically based on a PC, to configure e and
diagnose the individual IO devices (drive units).
IO devices: Drive units with PROFINET interface
SINAMICS S120 with CU320-2 DP and inserted CBE20
SINAMICS S120 with CU320-2 PN
SINAMICS S120 with CU310-2 PN

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals