Vector control
5.18 Synchronization
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
277
5.18
Synchronization
Description
You can synchronize a motor with the line supply using the "Synchronization" function and
an existing voltage sensing module VSM10 (to measure the line voltage). The connection to
the line supply or the required contactor control can be realized using the existing bypass
function or a higher-level control system.
Use of the bypass function supports temporary (for example, for maintenance work without
plant standstill) or permanent operation of the motor on the line supply.
Synchronization is activated with parameter p3800. A VSM10 which is assigned to a drive
(via DRIVE-CLiQ), measures the line supply voltage.
Requirement
Drive in the vector control mode with Voltage Sensing Module (VSM10)
Induction motor without encoder
Vector control
Features
Connector inputs for the actual voltage sensing of the motor via VSM10 (p3661, r3662)
Setting a phase difference (p3809)
Can be activated by parameter (p3802)

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals