Communication
11.2 Communication via PROFIBUS DP
Drive functions
774 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
11.2
Communication via PROFIBUS DP
11.2.1
General information about PROFIBUS
11.2.1.1
General information about PROFIBUS for SINAMICS
PROFIBUS is an open international fieldbus standard for a wide range of production and
process automation applications.
The following standards ensure open, multi-vendor systems:
International standard EN 50170
International standard IEC 61158
PROFIBUS is tuned for high-speed, time-critical data communication at field level.
Note
PROFIBUS for drive technology is standardized and descr
ibed in the following document:
PROFIdrive Profile Drive Technology
PROFIBUS User Organization e. V.
Haid
-und-Neu-Strasse 7, D-76131 Karlsruhe
Internet: (
http://www.profibus.com)
Note
Before synchronizing to t
he isochronous PROFIBUS, all of the drive object pulses must be
inhibited
- also for those drives that are not controlled via PROFIBUS.
PROFIBUS interface: The cyclic PZD channel is deactivated when the CBE20
is plugged in!
NOTICE
Destruction of the CU320-2 or other CAN bus nodes by connecting a CAN cable
Connecting a CAN cable to interface X126 of the CU320-2 can destroy the CU320-2 or
other CAN bus nodes.
Do not connect any CAN cable to the X126 interface.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals