Communication
11.3 Communication via PROFINET IO
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
849
11.3.10.2
PROFIenergy commands
Principle of operation
At the start and end of pauses, the plant operator activates or deactivates the pause function
of the plant/system after which the IO controller sends the PROFIenergy "START_Pause" /
"END_Pause" command to the PROFINET devices. The device then interprets the content of
the PROFIenergy command and switches off or on again.
You can call up device information via additional PROFIenergy functions. You can use these
to transfer the "START_Pause"/"END_Pause" command in plenty of time.
PROFIenergy control commands
Control commands
Description
START_Pause Switches from the operating state to the energy-saving mode
depending on the pause duration.
Switches from the energy-saving mode to the operating state
depending on the pause duration.
START_Pause_with_time_response Switches from the operating state to the energy-saving mode
and also specifies the transition times in the command re-
sponse.
END_Pause Switches from the energy-saving mode to the operating state.
Cancels a switch from the operating state to the energy-saving
mode.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals