Function modules
8.13 Additional controls for Active Infeed
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
591
8.13
Additional controls for Active Infeed
With the "Additional controls" function module, parameterizable bandstop filters (Page 39)
can be used with whose help path resonances can be attenuated.
The main application for these bandstop filters is in weak line supplies in which the
resonance point of the line filter can drop to one quarter of the controller frequency.
Activating the function module
1. Select the infeed in the project navigator and open the "Properties" shortcut menu.
The "Object properties" dialog then opens.
2. Click the "Function modules" tab.
3. Activate the "Additional closed-loop controls" function module in the function modules
selection with a mouse click.
Parameter r0108.03 indicates whether the function module has been activated.
Function diagrams (see SINAMICS S120/S150 List Manual)
8940
Active Infeed
- controller modulation depth reserve / controller DC link voltage
(p3400.0
= 0)
8946
Active Infeed
- current precontrol / current controller / gating unit (p3400.0 = 0)

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals