Function modules
8.7 Position control
Drive functions
506 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
The "position control" function module is integrated in the system as follows:
The configuration screen for "Position control" in STARTER is not made accessible unless
the function module "Basic positioner" is activated (r0108.4 = 1) which means that the
function module "Position control" (r0108.3 = 1) is automatically activated as well.
The "basic positioner" function module can be activated via the commissioning wizard or the
drive configuration (configure DDS) (configuration "Closed-loop control structure" - checkbox
"Basic positioner").
To ensure correct, error-free operation of the basic positioner, it is absolutely essential that
the "Position control" function module is activated and the position control correctly
configured.
If the "position control" function module is active, and to optimize the speed controller, a
function generator signal is interconnected to the speed controller input p1160, then the
position controller monitoring functions respond. To prevent this from happening, the position
controller must be disabled (p2550 = 0) and switched to the tracking mode (p2655 = 1, for
control using PROFIdrive telegram 110 PosSTW.0 = 1). In this way, the monitoring functions
are switched off and the position setpoint is tracked.
Function diagrams (see SINAMICS S120/S150 List Manual)
4010
- Actual position value processing (r0108.3 = 1)
4015
- Position controller (r0108.3 = 1)
4020
l - Standstill monitoring / positioning monitoring (r0108.3 = 1)
4025
- Dynamic following error monitoring, cam controllers
Overview of important parameters (see SINAMICS S120/S150 List Manual)
r0108
module
p1160[0...n]
CI: Speed controller, speed setpoint 2
p2550
BI: Position control enable 2