Servo control
4.1 Technological application
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
87
4.1
Technological application
Using parameter p0500, you can influence the calculation of open-loop control and closed-
loop control parameters. The default setting helps you find suitable values for standard
applications.
You can make preassignments for the following technological applications:
Value p0500
Application
100
Standard drive (SERVO)
101
Feed drive (limit current limitation)
102
Encoderless control down to f = 0 (passive loads)
An overview of the influenced parameters and the set values is provided in the "SINAMICS
S120/S150 List Manual".
Calculation
You call the calculation of the parameters, which influence the technological application, as
follows:
When exiting quick commissioning using p3900 > 0
When automatically calculating the motor/closed-loop control parameters with
p0340 = 1, 3, 5
When calculating the technology-dependent parameters with p0578 = 1