EasyManuals Logo

Siemens SIROTEC Function Manual

Siemens SIROTEC
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #235 background imageLoading...
Page #235 background image
Vector control
5.7 Closed-loop torque control
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
235
OFF responses
OFF1 and p1300 = 22, 23
Response as for OFF2
OFF1, p1501 = "1" signal and p1300 ≠ 22, 23
No separate braking response; the braking response is provided by a drive that
specifies the torque.
The pulses are suppressed when the brake application time (p1217) expires. Standstill
is detected when the actual speed value is less than the speed threshold (p1226) or
when the monitoring time (p1227) that started when speed setpoint ≤ speed threshold
(p1226) has expired.
Switching-on inhibited is activated.
OFF2
Immediate pulse suppression, the drive coasts to standstill.
The motor brake (if parameterized) is closed immediately.
Switching-on inhibited is activated.
OFF3
Switch to speed-controlled operation
n_set = 0 is input immediately to brake the drive along the OFF3 deceleration ramp
(p1135).
When standstill is detected, the motor brake (if parameterized) is closed.
The pulses are suppressed when the motor brake application time (p1217) has
elapsed. Standstill is detected when the actual speed value is less than the speed
threshold (p1226) or when the monitoring time (p1227) that started when speed
setpoint ≤ speed threshold (p1226) has expired.
Switching-on inhibited is activated.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals