Vector control
5.19 Voltage Sensing Module
Drive functions
280 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Identification via LED and firmware version
VSM identification via LED is activated via parameter p0154.
When p0154 = 1, the LED RDY on the relevant VSM flashes green/orange or red/orange at
a frequency of 2 Hz.
The firmware version of the VSM can be displayed using parameter p0158[0,1] on the
VECTOR drive object.
Function diagrams (see SINAMICS S120/S150 List Manual)
7020
Technology functions
- Synchronizing
9880
Voltage Sensing Mod
ule (VSM) - Analog inputs (AI 0 ... AI 3)
9886
Voltage Sensing Module (VSM)
- Temperature evaluation
Overview of the important parameters (see SINAMICS S120/S150 List Manual)
p0151[0...n]
Voltage Sensing Module component number
p0155[0...n]
Activate/de
activate Voltage Sensing Module
p0158[0...n]
Voltage Sensing Module firmware version
p3800[0...n]
Sync
-line-drive activation
p3801[0...n]
Sync
-line-drive drive object number

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals