Function modules
Drive functions
466 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
You can also activate function modules in STARTER under "Configuration" > "Function
modules / technology packages". Function modules that are grayed-out in STARTER cannot
be activated via STARTER.
Commissioning via parameter (only with BOP20)
Function modules can be activated/deactivated using parameter p0108 of the Control Unit
(CU).
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p0108[0..n]
Drive object function module
p0124[0...n]
Main component identification via LED