Function modules
8.7 Position control
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
501
The position controller is enabled by an AND link of the binector inputs p2549 (position
controller 1 enable) and p2550 (position controller 2 enable).
The position setpoint filter (p2533 time constant position setpoint filter) is a PT1 element, the
symmetrizing filter as dead time element (p2535 symmetrizing filter speed precontrol (dead
time) and PT1 element (p2536 symmetrizing filter speed precontrol (PT1)). The speed
precontrol p2534 (factor, speed precontrol) can be disabled via the value 0.
● Symmetrization (p2535, p2536)
● Limiting (p2540, p2541)
● Precontrol (p2534)
● Adaptation (p2537, p2538)
Note
We only recommend that experts use the position controller functions without using the basic
positioner.
Function diagrams (see SINAMICS S120/S150 List Manual)
4015
- Position controller (r0108.3 = 1)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p2533[0...n]
LR position setpoint filter time con
stants
p2534[0...n]
LR speed feedforward control factor
p2535[0...n]
LR speed feedforward control balancing filter dead time
p2536[0...n]
LR speed feedforward control balancing filter PT1
p2537
CI: LR position controller adaptation
p2538[0...n]
portional gain
p2539[0...n]
p2540
CO: LR position controller output speed limit
p2541
CI: LR position controller output speed limit signal source