Safety Integrated Basic Functions
10.9 Control via TM54F
Drive functions
706 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
F-DO signal sources
A drive group contains several drives with similar characteristics. The groups are
parameterized at the p10010 and p10011 parameters.
The following signals are available for interconnecting (p10042, ..., p10045) each one of the
four drive groups with the F-DO:
STO active
SS1 active
SS2 active
SOS active
SLS active
SSM feedback active
Safe state
SOS selected
Internal event
Active SLS level bit 0
Active SLS level bit 1
SDI positive active
SDI negative active
SLP active
Active SLP area
The following (safe state) signals can be requested via p10039[0...3] for each drive group
(index 0 corresponds with drive group 1 etc.):
STO active (power removed/pulses suppressed)
SS1 active
SS2 active
SOS active
SLS active
SDI positive active
SDI negative active
SLP active