EasyManuals Logo

Siemens SIROTEC Function Manual

Siemens SIROTEC
1094 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #761 background imageLoading...
Page #761 background image
Communication
11.1 Communication according to PROFIdrive
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
761
Number of elements:
08 hex → The actual fault incident with eight faults is to be read.
Parameter number:
945 dec → p0945 (fault code) is read.
Subindex:
0 dec → Reading starts at index 0.
Initiate parameter request.
If ZSW1.3 = "1" → Initiate parameter request
Evaluate the parameter response.
Parameter response
Offset
Response header Request reference mirrored =
25 hex
Response ID = 01 hex 0 + 1
Axis mirrored = 02 hex
Number of parameters = 01 hex
2 + 3
Parameter value
Format = 06 hex
Number of values = 08 hex
4 + 5
1st value = 1355 dec 6
2nd value = 0 dec
8
...
...
8th value = 0 dec
20
Information about the parameter response:
Request reference mirrored:
This response belongs to the request with request reference 25.
Response ID:
01 hex → Read request positive, values stored as of 1st value.
Axis mirrored, number of parameters:
The values correspond to the values from the request.
Format:
06 hex → Parameter values are in the unsigned16 format.
Number of values:
08 hex → Eight parameter values are available.
1st value ... 8th value
A fault is only entered in value 1 of the fault buffer for drive 2.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals