Simrad EK80 - Using a Steel Conduit to Protect the Transducer Cable

Simrad EK80
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
394149/C
105
Usingasteelconduittoprotectthetransducer
cable
Asteelconduitisusedtoprotectthetransducercable.
Itisstronglyrecommendedtolayasteelconduitfromthecableglandabovethetransducer
totheEK80transceiver,andtopullthetransducercablethroughthisconduit.
Thereareseveralreasonsforthis.
Itwillmakeiteasieratalaterstagetoreplacethetransducer.
Itwillprotectthecables.
Noiseandinterferencefromotherelectricalequipmentisgreatlyreduced.
Theriskofoodingisgreatlyreducedwhenthesteelconduitisterminatedabovethe
waterline.
WithasteelconduittheinstallationwillsatisfytheEuropeanUnionregulationsfor
electromagneticcompatibility(EMC)interference.Withoutasteelconduit,thereisariskof
reducedEK80performance.
Steelconduitqualityandshielding
Thesteelconduitmustbeunbrokenandwatertightfromthetransducertoabovethewater
line.Fromthere,thecablecanbepulledfurther,orajunctionboxcanbeinstalledto
facilitatefurtherconnections.
Note
Thesteelconduitmustactasacontinuouselectricalscreenalltheway.
Iftwoormoretransducersareinstalledclosetoeachotheritispossibletopulltheircables
inthesamesteelconduit,providedtheconduitdiameterisincreasedaccordingly.However,
foreasyreplacementitisrecommendedthateachtransducerhasitsownsteelconduit.
Steelconduitminimumdimensions
Thedimensionsofthesteelconduitmustbespeciedand/orveriedbytherelevant
maritimeauthorityand/orclassicationsociety.Theminimumdimensionsare:
35mminnerdiameter
6mmwallthickness(4.5mmifgalvanized)
Cablelayoutandinterconnections