Simrad EK80 - Setting up Depth Output to an External System

Simrad EK80
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
180
394149/C
softwareutilitytobeused.Ifthedatacommunicationissetuptoonlytransmit
information,thisparameterisnotrequired.
RemoteIPAddress:ThisistheInternetProtocol(IP)addressfortheremote
computer.Sinceyouareabouttoreceivedata,thisaddressisunessential.
RemotePort:Sinceyouareabouttoreceivedata,thisportisunessential.Keep
itsdefaultvalue.
cClickOKtosavethechosenparametersandclosetheLANPortSetupdialogbox.
12Verifythatthecommunicationportisfunctional.
aClickonacommunicationlinetoselectit.
bClickMonitortoopenthePortMonitordialogbox.
cVerifythatthedataowontheinputline(RxDatatexteld)isoperational.
Inordertomonitorthisdataow,theperipheralsystemmustbeactiveand
transmittinginformationtotheEK80.
dClickOKtoclosethePortMonitordialogbox.
Ifthedataowisnotpresent,wesuggestthefollowingactions:
Checkthattheperipheralsystemhasbeenswitchedon.
Checkthattheperipheralsystemisinfacttransmittinginformation.
Checkthecables.
Checkthatyouhavemadethephysicalconnectiontothecommunicationport
thatyouaremonitoring.
13ClickOKtosavethechosensettingsandclosethedialogbox.
Settingupdepthoutputtoanexternalsystem
ThedepthoutputfromtheEK80canbeexportedtoaperipheralsystem.
Prerequisites
Thisprocedureassumesthat:
YouhaveavacantinterfaceportonyourProcessorUnit.
YouarefamiliarwithNMEAandotherrelevantdatagramformats.
Youknowhowtosetuptheparametersforserialandlocalareanetwork(LAN)
communication.