394149/C
181
Context
Thecurrentdepthfromadenedtransceiverchannelcanbesentoutonaseriallineto
anexternalsystem.
ThedataisexportedonstandardNMEAdatagramformatsand/oronproprietaryformats.
Procedure
1ConnecttheperipheralsystemtoanavailablecommunicationportonyourProcessor
Unit.
ThisisdescribedintheCablelayoutandinterconnectionschapter.
2ClicktheOperationicon.
TheiconislocatedundertheMainmenu.ItisusedtoopentheOperationmenu.
3OntheOperationmenu,clickOutput.
ObservethattheOutputdialogboxopens.Thisdialogboxcontainsanumberofpages
selectedbythemenuontheleftside.
4OntheleftsideoftheOutputsdialogbox,selectDepthOutput.
ObservethattheDepthOutputpageopens.
5Setupthedepthoutputport.
aOntheDepthOutputpage,selectwhichoutputtype(datagram)toexport.
bClickAdd.
ObservethatDepthOutputCongurationdialogboxopenstocollectthe
communicationparameters.
cSelectthecommunicationportyouwishtouse.
dClickInspectPorttoverifythattheportparametersarecorrect.
Ifyouneedtoadjusttheportsettings,youmustselectI/OSetuptocorrectthis
after
youhavedenedtheoutputparameters.
eSelectwhichchannel(transceiverandfrequency)youwishtoexportthedepth
informationfrom.
Tip
Inmostcases,thelowestfrequencyisused.
fIfapplicable,denetheTalkerID.
Settingtowork