82
394149/C
Relatedtopics
ListofEK80cables,page82
Cableprocedures,page84
Cabledrawingsandspecications,page106
Basiccablerequirements,page138
ListofEK80cables
AsetofcablesisrequiredtoconnecttheEK80unitstoeachother,totherelevantpower
source(s),andtoperipheraldevices.
ThefollowingcablesareusedwhentheEK80issetupwithaWideBandTransceiver
(WBT).
CableSignalFrom/ToMin.requirements
C1ACpower
Uninterruptiblepowersupply/Ship
supply
2x1.5mm²+Ground
C2ACpower
ProcessorUnit/Uninterruptible
powersupply
2x1.5mm²+Ground
C3
GroundDisplay/Ground
1x6mm²
C4
GroundComputer/Ground
1x6mm²
C5
VideoComputer/Display
Seecomment1
C6
KeyboardComputer/Keyboard
Seecomment2
C7
Mouse
Computer/Mouse
Seecomment3
C8–C11
SerialExternaldevice/Computer
2x5x0.5mm²
C12–15USB
Externaldevice/Computer
Seecomment4
C16
EthernetComputer/Ethernetswitchor
transceiver
CAT5-ESTP(ShieldedTwisted
Pair)
C17
EthernetComputer/Ship'slocalareanetworkCAT5-ESTP(ShieldedTwisted
Pair)
C18–C19
Notused
C20
EthernetEthernetswitch/TransceiverCA T5-ESTP(ShieldedTwisted
Pair)
C21
Notused
C22
Notused
C23–C25
Notused
C26ACpower
Shipsupply/Transceiverpower
supply
2x1.5mm²+Ground
SimradEK80