Section 07 ELECTRICAL SYSTEM
Subsection 01 (IGNITION TIMING)
Select YES using the key ↔.
Press ENTER.
A30E23A
TIMING<1-8>:TIMING<1-8>:
Select a timing correction factor corresponding to
correction needed.
Example: Timing mark as verified with a timing
lightat3500RPMwastooearlyby2°. The cor-
rection factor programmed is no. 4.
Select correction factor no. 5. This will retard the
timing by 2° because the difference between cor-
rection factor no. 4 and no. 5 is - 2° (passing from
1° to - 1°).
A30E2HA
TIMING<1-8>:5
IGNITION CORRECTION FACTOR
CORRECTION FACTOR
PROGRAMMED IN MPEM
IGNITION TIMING
CORRECTION
2 3°
3 2°
4 1°
1 0°
5 -1°
6 -2°
7 -3°
8 -4°
Press ENTER.
A30E2GA
2. ENGINE SERIAL#
>1. TIMING ADJUST
3. CALIBRATION
Press ENTER.
A30E24A
TIMING<1-8>:5
PRESS ANY KEY...
The display confirms that correction factor has
been changed to no. 5.
Press any key.
A30E27A
MODIFY?
YES NO
If the new correction factor selected above is the
good one select NO and press ENTER. Otherwise
select YES to choose an other correction factor.
A30E2GA
2. ENGINE SERIAL#
>1. TIMING ADJUST
3. CALIBRATION
Press MENU.
mmr2004-Rev 255