DocID13902 Rev 15 136/1128
RM0008 Connectivity line devices: reset and clock control (RCC)
158
Bit 16 PLLSRC: PLL entry clock source
Set and cleared by software to select PLL clock source. This bit can be written only when PLL is
disabled.
0: HSI oscillator clock / 2 selected as PLL input clock
1: Clock from PREDIV1 selected as PLL input clock
Note: When changing the main PLL’s entry clock source, the original clock source must be switched
off only after the selection of the new clock source.
Bits 14:14 ADCPRE[1:0]: ADC prescaler
Set and cleared by software to select the frequency of the clock to the ADCs.
00: PCLK2 divided by 2
01: PCLK2 divided by 4
10: PCLK2 divided by 6
11: PCLK2 divided by 8
Bits 13:11 PPRE2[2:0]: APB high-speed prescaler (APB2)
Set and cleared by software to control the division factor of the APB High speed clock (PCLK2).
0xx: HCLK not divided
100: HCLK divided by 2
101: HCLK divided by 4
110: HCLK divided by 8
111: HCLK divided by 16
Bits 10:8 PPRE1[2:0]: APB Low-speed prescaler (APB1)
Set and cleared by software to control the division factor of the APB Low speed clock (PCLK1).
0xx: HCLK not divided
100: HCLK divided by 2
101: HCLK divided by 4
110: HCLK divided by 8
111: HCLK divided by 16
Caution: Software must configure these bits ensure that the frequency in this domain does not
exceed 36 MHz.

Table of Contents

Other manuals for ST STM32F101 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ST STM32F101 series and is the answer not in the manual?

ST STM32F101 series Specifications

General IconGeneral
BrandST
ModelSTM32F101 series
CategoryComputer Hardware
LanguageEnglish

Related product manuals