Starting System: 1I-7
5) Disconnect the starter motor lead wire (3) and
battery (+) lead wire (4).
NOTE
Be sure to disconnect the starter motor lead
wire (3) first, then disconnect the battery (+)
lead wire (4).
6) Remove the starter relay (5).
Installation
Install the starter relay in the reverse order of removal.
Starter Relay Inspection
B944H11906006
Inspect the starter relay in the following procedures:
1) Remove the starter relay. Refer to “Starter Relay
Removal and Installation (Page 1I-6)”.
2) Apply 12 V to “A” and “B” terminals and check for
continuity between the positive and negative
terminals using the multi-circuit tester. If the starter
relay clicks and continuity is found, the relay is ok.
CAUTION
!
Do not apply battery voltage to the starter
relay for five seconds and more, since the
relay coil may overheat and get damaged.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
Tester knob indication
Continuity test ( )
3) Measure the relay coil resistance between the
terminals “A” to “B” using the multi-circuit tester. If
the resistance is not within the specified value,
replace the starter relay with a new one.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance (Ω)
Starter relay resistance
3 – 6 Ω
4) Install the starter relay. Refer to “Starter Relay
Removal and Installation (Page 1I-6)”.
3
5
4
I944H1190016-02
(A)
“A”
“B”
I944H1190017-02
“A”
“B”
-+
To batteryTo starter motor
I649G1190022-02
(A)
I944H1190018-01