9C-4 Combination Meter / Fuel Meter / Horn:
3) Keep pushing the adjuster switch (1) for more than 4
sec.
Reset
4) Pointer will return to the starting point right after the
completion of the operation. In the case of the
pointer not returning to the proper position after
doing above, replace the combination meter unit.
Refer to “Combination Meter Removal and
Installation (Page 9C-2)”.
5) Turn the ignition switch OFF.
Engine Coolant Temperature Indicator Light
Inspection
B944H19306005
Refer to “Electrical Components Location in Section 0A
(Page 0A-7)”.
Inspect the engine coolant temperature indicator light in
the following procedures:
1) Lift and support the fuel tank. Refer to “Fuel Tank
Removal and Installation in Section 1G (Page 1G-
7)”.
2) Disconnect the ECT sensor coupler (1).
3) Connect the variable resistor (2) between the
terminals.
4) Turn the ignition switch ON.
5) Check the LED (3) and LCD (4) operations when the
resistance is adjusted to the specified values.
If either one or all indications are abnormal, replace
the combination meter with a new one. Refer to
“Combination Meter Removal and Installation
(Page 9C-2)”.
6) Connect the ECT sensor coupler and install the fuel
tank. Refer to “Fuel Tank Removal and Installation in
Section 1G (Page 1G-7)”.
Engine Coolant Temperature Removal and
Installation
B944H19306006
Refer to “ECT Sensor Removal and Installation in
Section 1C (Page 1C-3)”.
FI
1
I944H1930008-01
Time Ignition switch Adjuster switch (1)
PUSH
Reset
OFF
ON
0
4 sec.
10 sec.
I944H1930009-02
1
I944H1930010-01
Resistance LED (3) LCD (4) Water temperature
2.45 k and over OFF
19 °C (67 °F) and
below
Approx. 0.811 k OFF
Approx. 50 °C (122
°F)
Approx. 0.11 k ON ON
120 – 139 °C (248
– 282 °F)
0 (Jumper wire) ON ON
140 °C (283 °F)
and over
2
I718H1930009-05
3
4
I944H1930011-01

Table of Contents