12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 349
Interactive Command Set
LOGIN
Use this command to change the active logon name and access level. The user is
logged on as the new user name and access level when the password is verified.
Level 0
LOGIN [user name]
If you do not provide a user name, the system prompts you for one.
When you enter a user name, the system prompts you for a
password. The password entry is echoed as ‘*’ characters. If the
user name and password match an entry in the user table, the user
is logged on at the assigned access level. After five minutes
(default) of inactivity on the port, the user is automatically logged
off.
Level 1 Same as Level 0 operation
Level 2 Same as Level 0 operation
Level 3 Same as Level 0 operation
Level 4 Same as Level 0 operation
Remarks Use this command to access various levels of the system. This is
the only way to change access levels for a port.
If you lose the password, contact Symmetricom Global Services to
generate a new one. There is a GUEST entry, with a null password,
that is always present to gain access to Level 1.
Related BYE, USERS, DOY, COMM
Restrictions If no user passwords have been entered, this command is not
listed in help.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals