EasyManua.ls Logo

Telit Wireless Solutions LN940A11 SERIES - AT+IFC DTE-Modem Local Flow Control

Telit Wireless Solutions LN940A11 SERIES
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80591ST10886A Rev.2 Page 24 of 200 2018-07-02
<value>
Determines
the number of bits in the data bits, the presence of a parity bit, and the number of
stop bits in the start-stop frame.
[3]
8 data bit, 1 stop bit
<parity> D
etermines how the parity bit is generated and checked, if present; this sub parameter has no
meaning.
0 Odd (not supported)
1
Even (not supported)
2
Mark
[3]
None
4.11.
AT+IFC DTE-Modem Local Flow Control
This set command selects the flow control behavior of the serial port in both directions: from DTE to modem
(<by_ta> option) and from modem to DTE (<by_te>).
Syntax
Type
Command
Possible Return
Result
Instruction
Test Command AT+IFC=? +IFC: =(<by_te>list),
(<by_ta>list)
OK
-
Read Command AT+IFC?
+IFC: =<by_te>,
<by_ta>
OK
-
Write Command AT+IFC=<by_te>, <by_ta> OK -
Parameter Description
parameter
Value
Instruction
< by_te >
Flow control option for the data received by DTE
0 flow control None

Table of Contents