Syntax
Type
Command
Possible Return Result
Instruction
Read Command AT+ CFUN? +CFUN: 1
OK
-
Test Command AT+ CFUN=? +CFUN: (0-1,4-7),(0-1)
OK
-
Write Command AT+CFUN=<fun>[,<rst>] - -
Parameter Description
parameter
Value
Instruction
<fun> 0
Minimum functionality.
1
Full functionality.
4
Disable phone both transmit and receive RF circuits.
5
Set Factory Test Mode.
6
Set it Reset.
7
Set it Offline.
<rst> 0
Do not reset the MT before setting it to <fun> power level.
1
UE resets and restarts.
9.3.
AT+CPIN Enter PIN
This set command sends to the MT a password which is necessary before it can be operated (SIM PIN, SIM
PUK, PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall automatically repeat the PIN. If no PIN
request is pending, no action is taken towards MT and an error message, +CME ERROR, is returned to TE.
NOTE: SIM PIN, SIM PUK, PH-SIM PIN, PH-FSIM PIN, PH-FSIM PUK, SIM PIN2 and SIM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LN940A11 SERIES and is the answer not in the manual?

Telit Wireless Solutions LN940A11 SERIES Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLN940A11 SERIES
CategoryControl Unit
LanguageEnglish

Related product manuals