9960 Self-Propelled Peanut Combine Electrical System
MAN091 06/03/05 163
Specific Gravity Check
Check specific gravity of electrolyte in each
cell with a battery hydrometer to meter battery
condition. Charge battery if reading is below
1.215. Replace battery if difference between
cells is more than 0.050.
Always correct specific gravity reading for
electrolyte temperature variation. Add 0.0004
for every 10ºC above 27ºC). Subtract at same
rate in electrolyte temperature is below 80ºF
(27ºC). Corrected specific gravity of a fully
charged battery is 1.260.
CAUTION
Battery gas can exp
lode. Keep sparks
and flames away from batteries. Use
flashlight to check battery electrolyte level.
NEVER check battery charge by placing a
metal object across the posts. Use a
voltmeter or hydrometer.