Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
– Bring bubble levels -2- on ACC Setting Device - VAS6190- into
balance using adjustment screws -1-.
– Adjust vertical slits -4- on ACC Setting Device - VAS6190- so
that laser beam is vertically centered on sensor lens.
– Adjust the same front axle individual toe settings using fine
adjustment screw -3-.
– The difference between individual toe values must be less
than 6' or they must be the same.
– Bring bubbles -2- on measurement sensor -1- into balance.
– Now using laser beam -3- on ACC Setting Device - VAS6190- ,
check whether laser beam contacts sensor lens.
Note
♦
If the laser beam still meets the sensor lens at this step after
adjusting the same individual toe values, the ACC Setting De‐
vice - VAS6190- is aligned correctly (positioned).
♦
If the laser beam does not meet the sensor lens, ACC Setting
Device - VAS6190- alignment must be performed again.
– Connect -Vehicle Diagnostic Tester- .
Audi Q7 2007 ➤
Suspension, Wheels, Steering - Edition 01.2014
262 Rep. Gr.44 - Wheels, Tires, Wheel Alignment