EasyManua.ls Logo

Baumuller b maXX 5000 - Page 190

Baumuller b maXX 5000
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connections on the front side
Instruction handbook bmaXX 5000
Document No.: 5.09021.19 Baumüller Nürnberg GmbH
190
of 346
7.15
POWERLINK
®
Type code bmaXX 5000 with POWERLINK
®
:
BM5XXX-XXXX-XXXX-04XX
X3
X4
POWERLINK
®
IN
POWERLINK
®
OUT
Add-on modules
Number of bus connections 1 IN / 1 OUT
Bus connection RJ 45
Number of parameters refer to
parameter handbook b maXX 5000
Data size of parameters 16 / 32 Bit
Baud rates 10 / 100 Mbit/s
1: TX+
2: TX-
3: RX+
4: reserved
5: reserved
6: RX-
7: reserved
8: reserved
X3
X4
NOTE!
Only devices with type code BM5XXX-XXXX-XX01/03/04/05/06/07/08 provide an
add-on module!
The add-on modules are built-in and cannot be changed.
It is forbidden to remove the yellow front cover.

Table of Contents