412/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0127 Aborts a job
MID 0210 Subscription Output signal change
MID 0211 Upload Output signal change
Sent by: superordinate computer
This command can be used to abort a running job.
Note: If work is carried out directly in the OP using the PLC signals, the JobAbort signal has to be applied to input
OP 4.5.
Revision: 001 (supported by Rexroth OP)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Sent by: superordinate computer
As a consequence of this message, the superior computer is informed about every change in the configurable output
signals at the OP PLC module by means of a message (upload change in output signals, MID 0211).
After confirmed logon (command accepted, MID 0005), the tightening controller moreover sends a message (upload
change in the output signals, MID 0211) with the current assignment of the output signals to the superior computer.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005
Command error 0004 86 Activation for output signal change already available
Sent by: Tightening controller
The assignment of the output signals at the OP PLC module has changed.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: Number of signals, 8 bytes
Possible response MID Error no. Comment
Acknowledgement Upload output signal
change
0212