Engine and Control Systems
Engine Control Systems
80
Engine Control Systems
Sensor inputs and internal EMM controllers are
used to control the outboard’s engine operation.
Use Evinrude Diagnostics software to trouble-
shoot the sensors. Refer to the Fault Code Chart
for a complete list of all engine fault codes.
Internal Sensors
Internal sensors are NOT serviceable. Repro-
gramming or replacement may be required to
resolve EMM related issues.
EMM Temperature Sensor
Monitors the temperature of the fuel injector driver
circuits.
If the EMM temperature exceeds 176°F (80°C) or
the circuit fails, the EMM:
If EMM temperature exceeds 212°F (100°C) or
the circuit fails, the EMM:
IMPORTANT: The outboard will not restart until
the engine cools below 212°F (100°C) and the
EMM temperature returns to normal. Refer to
Shutdown Mode on p. 89.
If EMM temperature is less than -22°F (-30°C) or
the circuit fails, the EMM:
If sensor reads less than -67°F (-55°C) or greater
than 311°F (155°C) a sensor circuit fault is
detected and the EMM:
55 V Circuit Sensor
Monitors the EMMs 55 V alternator circuit.
If system voltage exceeds 57 volts, the EMM:
If system voltage is less than 45 V between 500
and 1000 RPM, or is less than 52 V above 1000
RPM, the EMM:
12 V Circuit Sensor
Monitors the EMMs 12 V alternator circuit.
If battery voltage exceeds 15.5 volts, the EMM:
If battery voltage is less than 12 V below 2000
RPM, or is less than 12.5 V above 2000 RPM, the
EMM:
5 V Circuit Sensor
Monitors the EMMs 5 V sensor circuit.
If sensor voltage is less than 4.75 volts, the EMM:
Barometric Pressure Sensor
Supplies the EMM with barometric pressure read-
ing to compensate for changes in altitude and air
density.
If the BP sensor reads less than 13 KPa or greater
than 119.0 KPa, or the sensor or circuit fails, the
EMM:
Activates S.A.F.E.
Stores fault code 25
Engine Monitor: TEMP display ON
Activates SHUTDOWN
Stores fault code 29
Engine Monitor: TEMP display ON
Stores fault code 24
Stores fault code 23
Activates S.A.F.E.
Stores fault code 18
Engine Monitor: CHECK ENGINE display ON
Activates S.A.F.E.
Stores fault code 17
Engine Monitor: CHECK ENGINE display ON
Stores fault code 27
Engine Monitor: BATTERY display ON
Stores fault code 26
Engine Monitor: BATTERY display ON
Stores fault code 78
Stores fault code 44

Table of Contents