CDM-625A Advanced Satellite Modem MN-CDM625A
Front Panel Operation Revision 4
6–22
The modem automatically selects the actual scrambler used for Normal, depending on the exact
operating mode:
If framing = IBS/D&I, the IESS-309 scrambler is used.
If Reed-Solomon is on but IBS/D&I is off, its frame synchronous scrambler is used per
IESS-310, App. H. An exception to this is legacy EF Data Reed-Solomon, which uses a
proprietary modified V.35 scrambler instead.
If framing = EDMAC/2/3 and Reed-Solomon is OFF, its frame synchronous scrambler is used.
If configured for TPC (Turbo) encoding and all of the above settings are off, the TPC frame
scrambler is used except for 8-QAM. For CDM-570 compatibility, TPC with 8-QAM uses the
V.35 scrambler.
ITU V.35 scrambler (Intelsat variant) is the default scrambler when all of the above settings
are OFF.
When you select IESS, the default ITU V.35 scrambler specified in IESS-315 takes priority over all
“normal” scramblers and is used instead. Therefore, for many operating modes, the two
scrambler selections are redundant.
When using TPC and Carrier-in-Carrier simultaneously, the IESS-315 (V.35) scrambler is the only
permitted choice.