CDM-625A Advanced Satellite Modem MN-CDM625A
Serial-based Remote Product Management Revision 4
8–3
All messages from Controller-to-Target require a response, with one exception: This will be either to return data that has been
requested by the Controller, or to acknowledge reception of an instruction to change the configuration of the Target. The exception to
this is when the Controller broadcasts a message (such as Set Time/Date) using Address 0, when the Target is set to EIA-485 mode.
8.4.1 Packet Structure
The exchange of information is transmitted, Controller-to-Target and Target-to-Controller, in ‘packets’. Each packet contains a finite
number of bytes consisting of printable ASCII characters, excluding ASCII code 127 (DELETE).
In this context, the Carriage Return and Line Feed characters are considered printable. With one exception, all messages from Controller-
to-Target require a response – this will be either to return data that has been requested by the Controller, or to acknowledge reception of an
instruction to change the configuration of the Target.
ASCII code 60
ASCII code 47
ASCII codes 61 or 63
ASCII code 13
EXAMPLE: <0135/TFQ=70.2345{CR}
ASCII code 62
(1 character)
(4 characters)
ASCII code 47
(1 character)
(3 characters)
ASCII codes
61, 63, 33, or 42
(1 character)
(From 0 thru n
Feed
ASCII codes 13,10
(2 characters)
EXAMPLE: >0654/RSW=32{CR}{LF}