EasyManua.ls Logo

Comtech EF Data CDM-625A - LNB Parameters (L-Band Device)

Comtech EF Data CDM-625A
756 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDM-625A Advanced Satellite Modem MN-CDM625A
Serial-based Remote Product Management Revision 4
8–61
8.5.9 LNB Parameters (L-Band Device)
Parameter
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
LNB
DC Power
Control
LPS=
Exception –
600L Emulation:
LNB & LNV
1 byte, 0 thru 3
Command or Query.
Sets or returns LNB DC Power Supply Control in the form x, where:
0=OFF
1=13V LNB Voltage
2=18V LNB Voltage
3=24V LNB Voltage
LPS=
LPS?
LPS*
LPS#
LPS?
Exception –
600L Emulation:
LNB & LNV
LPS=x
(see Description of
Arguments)
LNB
Reference
Enable
LNR=
1 byte, 0 or 1
Command or Query.
Sets or returns LNB Reference in the form x, where:
0=Disable LNB Reference
1=Enable LNB Reference
LNR=
LNR?
LNR*
LNR#
LNR?
LNR=x
(see Description of
Arguments)
LNB
Low Current
Limit
LNL=
3 bytes,
numeric
Command or Query.
Sets or returns LNB Low Current Limit in the form xxx, where:
xxx=Value, in mA, from 000 thru 500.
LNL=
LNL?
LNL*
LNL#
LNL?
LNL=xxx
(see Description of
Arguments)
LNB
High Current
Limit
LNH=
3 bytes,
numeric
Command or Query.
Sets or returns LNB High Current Limit in the form xxx, where:
xxx= Value, in mA, from 000 thru 500
LNH=
LNH?
LNH*
LNH#
LNH?
LNH=xxx
(see Description of
Arguments)
LNB
Current
N/A
4 bytes,
numeric
Query only.
Returns LNB Current in the form xxxx, where:
xxxx=Value, in mA.
N/A
LNC?
LNC=xxxx
(see Description of
Arguments)
LNB
Voltage
N/A
4 bytes,
numeric
Query only.
Returns LNB Voltage in the form xxxx, where:
xxxx=Value, in volts.
N/A
LVO?
LVO=xxxx
(see Description of
Arguments)

Table of Contents