CDM-625A Advanced Satellite Modem MN-CDM625A
Serial-based Remote Product Management Revision 4
8–48
Parameter
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Bulk Status Query
N/A
29 bytes
Exception –
600 or 600L
Emulation:
28 chars, as
RFO is different
Query only.
Response in the form abcccc,ddddd,eeffffffggggghhh, where:
a=LRS? response
b=RED? response
cccc=EBN? response
ddddd=BER? response
eeeee=BFS? Response
* ffffff=RFO? response
ggggg=RSL? response
hhh=TMP? response
NOTE: This command is intended to reduce the need for excessively frequent queries to a modem, and will be useful for a
unit in a redundancy system, where the redundancy system has monitoring of its own occurring. The latter 6 parameters are
only updated once per second.
N/A
BSQ?
BSQ=abcccc,ddddd,eef
fffffggggghhh
(see Description of
Arguments)