CDM-625A Advanced Satellite Modem MN-CDM625A
Telnet Command Line Interface (CLI) Operation Revision 4
9–27
Dialog Window Option Entry
F Rx Frequency
Enter an Rx Frequency as follows:
• Range 1 – From 50.0000 to 180.0000 MHz
•
Range 2 – From 950.0000 to 2250.0000 MHz
G Rx Spectrum Invert Use the ↑↓ arrow keys to select Normal or Inverted
Use the ↑↓ arrow keys to select Off, Normal, or IESS315
I Rx Acq Sweep Range Enter a value from 1 to 200 kHz
J
Use the ↑↓ arrow keys to select Normal, IESS410, EF Data, or IBS
Rx Data Invert
Typical for either entry – Use the ↑↓ arrow keys to select Normal or Inverted
L Rx Data Clock Invert
M Rx Ternary Code Use the ↑↓ arrow keys to select AMI, B8zs, B6zs, or Hdb3
N Rx EbNo Alarm Point Enter a value from 0.1 to 16.0 dB
O Rx Equalizer Enable Use the ↑↓ arrow keys to select Disabled or Enabled
Use the ↑↓ arrow keys to select Off or On
Q Rx Submux Ratio
Use the ↑↓ arrow keys to select the IP/Synchronous setting:
• 1/9 • 1/8 • 1/7 • 1/6 • 1/5 • 1/4
• 2/7 • 1/3 • 2/5 • 3/7 • 1/2 • 3/5
• 2/3 • 3/4 • 4/5 • 1/1 • 5/4 • 4/3
• 3/2 • 5/3 • 2/1 • 7/3 • 5/2 • 3/1
• 7/2 • 4/1 • 5/1 • 6/1 • 7/1 • 8/1
• 9/1 • 1/59 • 1/39 • 1/19
Use the ↑↓ arrow keys to select an Rx Rolloff Factor of 0.12 or 0.35