CDM-625A Advanced Satellite Modem MN-CDM625A
Appendix K Revision 4
K–14
K.6 Ethernet Redundancy
Once you have determined the best configuration for near-to-far end Ethernet networks, you
may add the appropriate redundancy switches to one or both ends of the link(s):
1:1 Redundancy
is supported using either a CRS-170A L-Band 1:1 Redundancy Switch or a
CRS-180 70/140 MHz 1:1 Redundancy Switch, and a user-provided, off-the-shelf Ethernet
switch.
1:N Redundancy
is supported using a CRS-300 1:10 Redundancy Switch or a CRS-500 M:N
Redundancy System in 1:N mode (in a wired-thru or wired-around configuration), and is
supported in Single-Port Ethernet Bridge (Managed Switch) and Router Modes (the
optional IP Packet Processor is required for Router Mode).
Packet Processor Redundancy
is supported in both 1:1 and 1:N redundant configurations
using the CRS-500 M:N Redundancy System.
Refer to the pertinent switch Installation and Operation Manuals for detailed information on
using the CDM-625A in a redundancy configuration.