SLM-5650B Satellite Modem
Revision 2
Appendix C C–41 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Initialize Statistics
Pointer
ISP= None Command only.
Resets internal pointer to allow RNS? queries to start at the
beginning of the stored statistics log.
Example: ISP=
ISP=
ISP#
N/A N/A
LoopBack Test
Modes
LOP= 1 byte Command or Query.
Loopback Test Modes, where:
0 = Normal Mode (no test)
1 = IF Loopback
2 = I/O Loopback #1
Example: LOP = 1 (IF Loopback)
LOP=
LOP?
LOP*
LOP#
LOP? LOP=x
(see Description
of Arguments)
Local/Remote
Status
LRS= 1 byte Command or Query.
Local/Remote status, where:
0 = Local
1 = Serial Remote Control
2 = Reserved
3 = Serial + Ethernet Remote Control
Example: LRS = 1 (selects Serial Remote)
LRS=
LRS?
LRS*
LRS#
LRS? LRS=x
(see Description
of Arguments)

Table of Contents