D 21 12
"Paving parameters" menu
Menu for showing and adjust-
ing the paving parameters.
A
Press the adjacent function
button (B) to call up the men-
us.
Set-up menu
Paving parameters
- (1) Left conveyor speed
(%) display and adjustment
parameters
- (2) Right conveyor speed
(%) display and adjustment
parameters
- (3) Left auger speed (%)
display and adjustment pa-
rameters
- (4) Right auger speed (%)
display and adjustment pa-
rameters
- (5) Nominal vibration speed
(RPM) display and adjustment parameters
- (6) Nominal tamper speed (RPM) display and adjustment parameters
A
Tamper and vibration range depending on screed type.
(see operating instructions for the screed)
A
Press the adjacent function button (D) to save the paving parameters in the parame-
ter memory.
A
Press the adjacent function button (E) to call up the paving parameters from the pa-
rameter memory.