EasyManua.ls Logo

Dynapac SD2500C - General visual inspection

Dynapac SD2500C
480 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F 100 3
2 General visual inspection
The daily routine should comprise a visual inspection around the entire paver finisher.
The following items must be checked:
- Are components or controls damaged?
- Are there leaks on the engine, the hydraulics, the gearbox, etc.?
- Are all fastening points (conveyor, auger, screed, etc.) in order?
- Are the warnings affixed to the vehicle complete and legible?
- Are the non-slip surfaces at ladders, steps, etc. in correct condition, not worn
or soiled?
m
Immediately take actions to correct any detected malfunction to avoid damages, dan-
gers or environmental hazards!
3 Check that the bolts and nuts fit firmly
Bolts and nuts must be checked regularly to ensure that they fit firmly; retighten them
if necessary.
A
The spare parts catalogue states the special torques at the corresponding parts.
A
For the necessary standard torques, please refer to the section "Bolts - torques"
Caution! Possible damage to or destruction of parts!
- Self-locking nuts must always be replaced after removal.
- Special torques not mentioned in this manual are stated
at the corresponding place in the spare parts catalogue.
- Screws locked with screw cement must be cemented in
again if found to have come loose.
Always use the stated torque.
- Stated torques for screwed connections apply
to dry (unoiled) state
- Do no reuse screws inserted with the maximum permit-
ted torque; instead, replace with new screws.
- Screws in strength class 12.9 should only
be used once.
- All screwed connections must be clean.
- Check all reused components of the screwed connection
for any signs of damage.
NOTE

Table of Contents