E 10 43
Mounting and aligning the sensor
- Insert the sensor mounting (13) into the bracket (14) and secure with a wing
nut (15).
- Align the angle between the sensor and reference and secure with the relevant
clamping bolt (16).
A
The sensor and reference must be at right angles to each other!
- The sensing height can be set by loosening the fixing screw (17).
A
The reference should run centrally along the sensor.
- The sensor's distance from the reference can be set by loosening the fixing
screw (18).
A
The distance between the sensor and reference (cable) should be 350 mm!
A
All assembly parts must be mounted and tightened properly to ensure safe and
precise operation of the automatic steering unit!
Connecting the sensor
A
A sensor for connecting the sensing system to the vehicle's control system is located
on the left and right sides of the vehicle on the inner side of the bumper.
- Connect the relevant connection cable (19) to the socket (20) and sensor (21).
A
A connection socket for the automatic steering unit is located on both sides of the
vehicle.
m
Route the connection cable so that it cannot be damaged during operation.
m
Seal unused sockets with the relevant protective caps.