F 40 8
Auger box (4)
Check oil level
A
In case of correct oil level, the oil is
between the two notches of the
dipstick (A).
For filling in the oil:
- Unscrew screws (B) from the top cov-
er of the auger box.
- Take off the cover (C).
- Fill up oil to correct level.
- Reinstall the cover.
- Use dipstick to check level again.
Change oil
A
The oil should be changed when at oper-
ating temperature.
- Place a suitable collecting container
under the auger box.
- Loosen bolts (D) from the circumfer-
ence of the worm shaft flange.
A
The oil runs out between the flange and
auger box.
- Drain out all oil.
- Correctly retighten flange bolts (D) di-
agonally.
- Pour the specified oil in through the
open top cover (C) of the auger box
until the oil level has reached the cor-
rect level on the dipstick (A).
- Correctly reinstall the cover (C) and
screws (B).