D 30 33
Central lubrication system (o)
The central lubrication system is activat-
ed in automatic mode as soon as the
drive engine is started.
- Pumping time: 4 min
- Pause time: 2 h
m
It is prohibited to change the factory-set
durations of pumping and break without
consulting the technical customer serv-
ice!
A
Changing the duration of lubrication and
breaks may be necessary when laying
mineral or cement bound material mix.