F 60 4
Item
Interval
Maintenance point Note
10
50
100
250
500
1000 / annually
2000 / every 2 years
If necessary
4
q
- Pump distribution gear -
Check oil level
q
- Pump distribution gear -
Top up oil
q
- Pump distribution gear -
Change oil
q
- Pump distribution gear -
Check bleeder
q
- Pump distribution gear -
Clean bleeder
5
g
q
- Hydraulic hoses -
Visual inspection
g
q
- Hydraulic system
Leak test
q
- Hydraulic system
Retighten screw connections
qq
- Hydraulic hoses -
Replace hoses
6 qq
- Auxiliary flow filter-
Replace filter element
(o)
Maintenance q